Advanced Ergonomic Technologies - AET
AET are leading experts in commercial office underfloor air
conditioning systems, having advised and overseen the installation
of over 65 million square feet throughout the world in a wide
variety of climatic conditions and cultures. AET's Flexible Space System, a
modular, standardised system has been the clear UK market leader for
a number of years and has a proven track record in use. With today’s
emphasis on reducing energy usage wherever possible, AET have now
added an all-air free cooling underfloor system called PleinAir to
their range. This variable air volume system includes a ground
breaking modulating damper to overcome the problem of the lack of
air circulation traditionally associated with VAV systems.
What is Underfloor Air Conditioning?
-
Sometimes called UFAD, underfloor air
distribution utilises the space beneath raised access flooring
(plenum), very often, but not exclusively in commercial office
operations
-
Air is supplied at floor level & may return
either through the floor or at high level
Why Choose Underfloor Air Conditioning?
-
Only a very small increase in the space for
the distribution of power, data & telephones beneath the raised
access floor is necessary for inclusion of air distribution, so
making more efficient use of the building’s volume
-
Height saving over ceiling based systems
either in refurbishment or new construction because of the
reduced need or even abolition of ceiling ducting
-
Comfort levels are high with easy resolution
of any draught or overheating issues
-
Flexibility is ensured as air delivery is
made through easily relocatable raised access floor panels
-
Tax advantages are realised as the floor
system may be classed as Plant & Equipment, so attracting
improved Capital Allowances
-
Floor-based components are easily to fit
retrospectively in Shell & Core scenarios in a raised floor
void, so saving initial capital expenditure
-
Architectural freedom in the ceiling is
guaranteed if there is no need for ceiling ducting
Operation of the Original Flexible Space System
-
Floor standing, super quiet air handling
units serve zones of 100-300m˛
-
Silicone coated baffle material separates the
supply & return plena
-
Treated air is delivered into the supply
plenum
-
Fan-assisted terminals supply air from the
plenum into the space above
-
They are connected only by power & data
cabling – there are no ducts
-
Local control may be tempered by centrally
set parameters
-
Adjacent users may control both airflow &
temperature
-
The system also facilitates central
monitoring & control
-
Spent air is drawn back into the return
plenum through grilles in the floor
-
Optional ceiling-return systems are available
-
Fresh air is introduced into the return air
path
-
Air is cooled or warmed at the AHU by water
delivered from central plant
-
Riser requirements are minimal
-
Remote control optional
-
Anodised aluminium grilles are rectangular in
shape
Operation of the New PleinAir System
-
Pressurised air may be supplied to the plenum
by central plant or local air handling units
-
100% free cooling using central station air
handling units
-
Air is returned at high level
-
In cooling mode, passive tile units (PTUs)
deliver air into the workspace
-
PTUs have a unique time modulated air damper
for excellent throw
-
In heating mode, a fan-powered hot water or
electrical unit heats recirculated office air
-
Options for cooling only or heating/cooling
PTUs available
-
Wide variety of grille configurations,
colours & shapes
-
Both variable & constant volume tile units
are available
-
Local PTU control is an option
-
PTU connected only by power & data cabling –
there may be minimal ductwork in the plenum
-
Bacnet IP controls
AET would be delighted to discuss the comparisons
and advantages of either the Flexible Space or PleinAir systems for
your project.
Request information:
Hiross AET
Underfloor Air Conditioning
Request information:
Above
Advanced Ergonomic Technologies Demountable Office Partitioning Movable
Partitioning Storage Wall Systems
Technical information associated with:
AET Raised Flooring Underfloor Air Conditioning
Technical information associated with:
AET Hiross Flexible Space
Underfloor Air Conditioning |

Traditional VAV Terminal
Reduced volume = Reduced throw
PleinAir with Time Modulating Dampers
Both diagrams show air being delivered at the same volume. The Time
Modulating Damper (shown below) delivers air from selected grilles in 6
second sequences, so giving improved air movement at all part-load
conditions.
Time Modulation Terminal