Tyco Raychem T2 Underfloor Heating Ramp Heating Product Selection

Information from Tyco Raychem

Tyco Raychem T2 Underfloor Heating Ramp Heating Product Selection
Tyco Raychem T2 Underfloor Heating Ramp Heating Product Selection

Tyco Raychem T2 Underfloor Heating Ramp Heating Product Selection

Request Information on other Products

Contact Raychem Tyco Raychem

Request Quote or Pre-Tender information

Request CPD Seminar

Information from Tyco Raychem

 

Subscribe to Newsletter

Employers - Advertise Job or Position

Submit Candidates Curriculum Vitae

Building Design Home

Contact Building Design

Advertise your Company on Building Design

Terms of Use

Links

Under Floor Heating Systems

Snow Melting Systems

Ramp Heating Systems

Energy Efficient Heating & Cooling

Trace Heating

Underfloor Heating

Tyco Raychem T2

 

Selecting Underfloor Heating System

Select the right underfloor heating system using the table below:

Tyco Raychem

Power Output Requirements:

Ensuring the heated floor reaches a comfortable, efficient, and safe temperature is an important requirement of the building regulations.

Raychem's SlabHeat software is a surface heating output modelling tool providing finite element analysis of the floor surface. The actual floor profile can be modelled to ensure the correct surface temperature is achieved.

Product Data Sheets

Full product specification and data sheets are available at:
www.Raychemfloorheating.com

Project Design

Our design software will provide key information for your client and contractor.

  • Complete bill of materials

  • Installation plan (2D & 3D version)

  • Product part numbers for easy quotation request

  • Circuit sizes & layout

  • Heat outputs per area

T2
Typical 2D Installation Plan

Building Regulation Compliance Information

Raychem floor heating systems are designed to enable Part L compliance in conjunction with Raychem zone controls and suitable floor insulation.

For compliance, support and further information on the new 2010 building services compliance guide,please contact us on tel: 0800 969 013.

Raychem Ramp Heating

For a complete guide to ramp and surface heating systems, please contact

Tyco Thermal Controls (0800 969 013)and request our new ramp heating technical handbook (document reference CDE-1540) available free of charge.

Underfloor Heating

 

For a FREE Slabheat report, call 0800 969 013
(Please mention that you have seen the Electrical Engineers’ Notebook)
 

Click here for printable PDF of this page

 

 

Request information:
Raychem Trace Heating Systems HWAT Hot water temperature maintenance

Request information:
Raychem Electrical Underfloor Heating Electric under floor heating T2 electrical floor heating

 

Tyco Thermal Controls (UK) Ltd
3 Rutherford Road
Stephenson Industrial Estate
Washington
Tyne & Wear
NE37 3HX

Email this company

Tel : 0800 969 013
Fax : 0800 968 624


 

 

 

Request further information:- please provide contact details: For UK and Europe only * Mandatory

 

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

 

 

*Please provide the project name and/or a short description of your requirements

Validation :
Please enter numbers shown



Request information : Tyco Raychem T2 Underfloor Heating Ramp Heating Product Selection

see also underfloor heating
 

Electrical Index

 

Ackermann Interact Underfloor Power

AF Switchgear Considerations in the Specification of LV Switchboards

AVK|SEG Uninterruptible Power Supplies UPS Design Guidance

AVK|SEG Standby Generation Design Guidance

AVK|SEG Containerised Gensets Canopied Gensets Protection Relays

B&P Security Services CCTV BS EN 5013-7 Design Guidelines

Broadcrown Standby Generators Technical Data 1

Broadcrown Standby Generators Technical Data 2

Cablofil Technical Solutions Armoured Cable Baskets/Ladders Cable Management

Cummins UK Total Power Solutions Standby Gas Generation Diesel

Cummins UK Total Power Solutions Diesel Generation Mobile Generators Sets Packaged Standby

Direct Generation Limited Technical Data

EAE Elektrik EAE Busbar Systems Busbar Technical Characteristics

Eaton Electric Eaton Engineering Services Eaton Engineering Systems

Electrium Sales Residual Current Devices Specifications

Electropatent underfloor track floor boxes floor grommets

Emergi-Lite Emergency Lighting

Hawker Siddeley FKI MV switchgear ratings MV switchgear specifications

Furse Lightning Protection and Transient Overvoltage Protection

Gent by Honeywell Fire Sensor Application Guide

Hager Miniature Circuit Breakers

Hitec UPS Dual Output Design Guide

Hitec UPS System Configurations Part 1

Hitec UPS System Configurations Part 2

Hitzinger Dynamic UPS diesel UPS dynamic diesel UPS

Hitzinger Dynamic UPS Diesel UPS Technical Data

HVMS High Voltage Solutions High Voltage Engineering Solutions

HVMS High Voltage Services High Voltage Engineering Services

Icel Summary of Generator Set Ratings

Lucy MV Distribution Switchgear Product Selection

Lumitron Lighting Reflectance Lumitron Lighting Compliance

Mardix Switchgear iPDU Specification Switchgear Specification

Marshall-Tufflex Data and Power Cabling Management Systems

Merlin Gerin Different Forms of Separation

Merlin Gerin Merlin Gerin MV Switchgear Dimensions

Merlin Gerin MV Switchgear Protection

MK Electric Compliance with Part M Building Regulations

OSRAM Electronic Control Gear

OSRAM T8 Flourescent Tubes

Piller UPS Application Design Guidance 1

Piller UPS Application Design Guidance 2

Piller UPS Application Design Guidance 3

PMA UK Ltd Flexible Conduits

Power Capacitors Capacitor Maintenance Power factor correction equipment

PRI Excerpts From The Metering Essentials Handbook An Introduction To Metering Basics

Profile Lighting Building Regulations Effect on Lighting Design

Prysmian Fire Resistant Cabling Systems

Riegens Lighting Guide 7 - LG7

Sarel Electrical enclosures Sarel Enclosures Guide Sarel Enclosures

Siemens Barduct Busbar Specification

Siemens Barduct Busbar Systems Busbar Typical Specification Clauses

Siemens Building Technologies Fire Detection Systems Fire Alarm Systems

Siemens intruder alarms CCTV door access Security systems

Square D MCBs Technical Data

Square D Technical MCBs Data 2

Thomas & Betts Cable Management Systems termination lugs Cable Fasteners

Tyco Electronics Switchgear Guide to Type Testing

Tyco Pyrotenax Specialist Cable Systems Pyrotenax Technical Specifications

Tyco Raychem T2 Underfloor Heating Tyco Raychem T2 Ramp Heating

Tyco Thermal Controls TraceTek Leak Detection TraceTek Design Guide

Underwoods Space Planner SENplus Front Access Switchboard packaged

Underwoods Switchgear Space Planner Echelon3200 Front Access Echelon3200

Uninterruptible Power Supplies Ltd UPS supplier UK Static 3 phase UPS

Wieland Modular Wiring Wieland Modular Wiring Specifications BS61535

 

Building design directory Site Map
Page p1 p2 p3 p4 p5 p6 p7 p8 p9 p10 p11 p12 p13 p14 p15 p16 p17 p18 p19 p20 p21 p22 p23 p24

See also
Building Design News  |  Building Design Recruitment  |  Building Design Tenders

| Building Design Home | Request informationArchitectural CPD Seminars | HVAC CPD Seminars | Electrical CPD Seminars |
| Architectural Technical Pages Index | Electrical Technical Pages Index | Mechanical Technical Index | Discussion Help | News |

| F1 | F2 | F3 | F4 | F5 | A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products | Terms of Use |

Catalogue Requests
| Architectural Request Index | Catalogue Request Index 1  | Catalogue Request Index 2Catalogue Request Index 3 |
| Catalogue Request Index 4 | Catalogue Request Index 5 | Catalogue Request Index 6 |

Useful building design and construction links - | Links Directory |





Recruitment
| Architect Jobs | Electrical Engineer Jobs | Building Engineering Jobs | AutoCad Operator Jobs | Structural Engineer Jobs | Links |

Arundel Jones Associates LLP | Tel : 01622 745333 | e-mail |