Advanced Ergonomic Technologies - AET Flexible SpacePleinAir Underfloor Air Conditioning SystemsAn all air underfloor VAV system using passive tile units and the revolutionary Air Fixture damper with Time Modulation control.
PleinAir Fan Powered Heater UnitsUnderfloor electric or water Fan Powered Heater Units for warming recirculated office air when boosted heating is required over and above any warmth provided by central or local plant. Ducts run from a Heating/Cooling terminal, through the heater and then on to another Heating/Cooling terminal for delivery of warmed air into the space. The Fan Powered Heater Units, which have the latest DC motors and plug fan technology, only run during the heating cycle. The unit shown, UFE, is an electrically heated model and the nominal air flow ranges from 70 – 700 l/s. Heat options range to 9kW in electric models or 1-2 row water coils. PleinAir Heating/Cooling VAV Passive Tile Units
Variable Air Volume terminal units either deliver
centrally or locally conditioned air direct from the plenum into the
occupied space using high capacity induction grilles. The units
incorporate a bespoke time modulation damper based on a 6 second cycle.
This feature allows only a proportion of the units in each space to open
at one time in low flow situations, so maintaining an acceptable
velocity which overcomes the problem of poor air circulation normally
associated with VAV systems. Communication is via the PCC system –
PleinAir Control Cabling - using BACnet IP and may be linked to a BMS. PleinAir Constant Volume Tile Units
The simplest of the PleinAir tile units, the constant
volume models deliver conditioned air at the temperature and volume
determined by the underfloor supply. The tile units come complete with a
personal control adjustment and debris collection tray. Accessible from
above, a knurled ring adjusts a damper under the grille allowing users
to vary the airflow direction and volume. The tile units can be
installed from above in a matter of minutes using the central Allen key
feature.
Click here for a printable PDF of this page
|
Advanced Ergonomic
Email this company
|
||||||||||||||||||||||||||||||||||||||||
Request information associated with: AET Raised Flooring Underfloor Air Conditioning
| Building Design
Home | Request information | Architectural
CPD Seminars | HVAC CPD
Seminars | Electrical CPD
Seminars |
| Architectural
Technical Pages Index |
Electrical Technical
Pages Index |
Mechanical Technical Index | Discussion
Help | News |
| F1 |
F2 |
F3 |
F4 |
F5 |
A1 |
A2 | A3 |
A4 |
A5 | Architectural Products |
HVAC Products |
Electrical Products | Terms of Use |
Catalogue Requests
| Architectural Request
Index |
Catalogue
Request Index 1 |
Catalogue
Request Index 2 |
Catalogue
Request Index 3 |
|
Catalogue Request Index 4 |
Catalogue
Request Index 5 |
Catalogue
Request Index 6 |
Useful building design and construction links -
| Links Directory |
Recruitment -
| Architect Jobs |
Electrical Engineer Jobs |
Building Engineering Jobs |
AutoCad Operator Jobs |
Structural Engineer Jobs |
Links |